# Device health: power supplies, fans and polling

A device can be up, answering ping and passing traffic while it is quietly losing
redundancy: one of two power supplies dead, a fan stopped, polls timing out half the time.
This guide covers where NetSense shows that, which devices report it, and how to get an
alarm before the second component goes.

## The Health panel

Every device page opens on **Overview**. The right-hand column starts with a health
panel named after the device type: **Switch Health**, **BNG Health**, **OLT Health** and so
on. It shows:

- **CPU**, **RAM** and **Temp.** with a 3-hour spark each. Servers show **Phys. Mem.**
  instead of RAM.
- **Power**: one small bar per power supply, labeled **PWR1**, **PWR2** and so on, when the
  device reports its power supplies (see [below](#which-devices-report-power-supplies-and-fans)).
- **Down Ports** (and on OLTs **Down PON Ports** and **Down ONUs**) and **Active Alarms**.

The right-hand column is hidden on narrow windows. If you do not see it, widen the browser
window or zoom out.

![The Switch Health panel with CPU, RAM and temperature, two healthy power supplies with the PWR 1: OK tooltip, and the Fans section listing four fan trays and two power-supply fans with their speed in rpm](https://netsense-nms.com/docs/_nimbus/md/nlb6t5/health-psu-fans.png)

### Power supplies

Each **PWR** bar is one power supply. Hover it for its state:

| Bar | Tooltip | Meaning |
| --- | --- | --- |
| Green | **OK** | The power supply is working. |
| Red, pulsing | **Offline** | The power supply failed or lost its feed. |
| Gray | **Not Inserted** or **Not Present** | The slot is empty, or the device reports the slot without a unit. |

A red bar on a device with redundant supplies is the one to act on: the device still runs,
but the next failure takes it down. It also matters during an outage. A device that goes
down with one supply already offline points to a power problem at the site rather than a
fiber cut.

Most devices report their supplies as working or failed and nothing in between. On
MikroTik, a supply that is installed but unplugged reads the same as a failed one.

PSU status is part of the device-level readings in alarm rules (Switch, BNG and OLT report
types). See [Creating alarm definitions](https://netsense-nms.com/docs/guides/alarm-definitions/).

## Fans

On switches and BNGs, the Overview has a **Fans** section under the health panel, listing
every fan the device reports with its name and speed:

- Speed is shown in **rpm** or as a **percentage**, depending on the vendor. Huawei reports a
  percentage of full speed; most other vendors report rpm.
- Vendors that report only a status show **Online** or **Offline** without a speed.
- A fan that is online but **not spinning** (speed 0) is shown in **amber**.
- An **offline** fan is shown in **red**, and the number of offline fans appears as a red
  badge on the **Fans** header, so it is visible even with the section folded.
- Empty fan slots are folded into one line, for example "3 empty slots". Hover it to see
  which slots are empty.

The section appears only when the device reports at least one fan. Fanless hardware, such
as the smaller MikroTik CRS switches, has no Fans section.

### Alerting on a fan

NetSense does not create a fan alarm for you. Add one under **Alarms → Alarm Definitions**
with the report type **Fan** (it needs `alarm:rule:edit`, and `switch:view` or `bng:view`
to pick the type). The rule fields are the fan's status, speed, slot and name, the
hostname, and the device's manufacturer, model and versions.

**Each fan raises its own alarm**, named after the fan. A second failed fan on the same
device opens a second alarm instead of hiding behind the first.

Two rules that work well:

```txt
Fan failed (Major, alert delay 10 minutes):
    status  =  Offline

Fan running hot (Warning, alert delay 30 minutes, Huawei only):
    manufacturer  =  Huawei
    speed         >= 80
```

Speed is a percentage on Huawei and rpm elsewhere, and the rule cannot tell the two apart.
Always scope a speed rule by manufacturer or model. A message such as
`Fan {{Name}} on {{Hostname}} ({{Model}}): speed {{Speed}}` tells the on-call engineer
which tray to look at.

![A new alarm definition named Switch fan failed with severity Major, report type Fan, alert delay 10 minutes, and a rule that fires when a fan's status is Offline](https://netsense-nms.com/docs/_nimbus/md/122oqif/health-fan-alarm.png)

Step-by-step definition building, delays and relays are covered in
[Creating alarm definitions](https://netsense-nms.com/docs/guides/alarm-definitions/) and
[Alarm timing](https://netsense-nms.com/docs/guides/alarm-timing/).

## Which devices report power supplies and fans

Power supply status is collected on switches and BNGs since release 1.74 and fans since
1.77. Both come from these switch and router families:

- Huawei (VRP switches, CloudEngine, NetEngine) and FutureMatrix
- Cisco IOS and IOS-XE, NX-OS, and SG350
- Juniper
- Nokia 7250 and 7750
- Arista
- Edgecore
- Dell
- Raisecom
- MikroTik
- D-Link DGS-1510
- Optilink MEN99216B
- SONiC

What a given device shows still depends on its model and firmware:

- Models with a single fixed power supply often report no supply at all, so no **Power**
  row appears. On MikroTik only chassis with two power supplies report them.
- Some older Huawei VRP firmware does not report power supplies.
- Fanless models have no **Fans** section.

If a model in this list shows nothing after a few polls, tell Extreme Labs support the model
and firmware version. Vendors and models are listed in
[Supported vendors](https://netsense-nms.com/docs/reference/supported-vendors/).

On OLTs, the **Power** row appears where the OLT integration reads its power supplies. OLTs
have no Fans section.

## The Poller tab: how well a device answers

Every OLT, switch, BNG, server and wireless device page has a **Poller** tab. It shows how
long each SNMP poll of this device took and whether it completed, compared with the average
for the same model.

![The Poller tab of a switch over the last 24 hours: the polling duration chart with its dashed model-average line and the SNMP query count, the summary boxes, and the first polls in the table, all completed](https://netsense-nms.com/docs/_nimbus/md/iys3yi/health-poller.png)

The **Polling Performance** panel starts collapsed: click its header to open it. It has a chart of **Duration (s)** and **SNMP queries** per
poll, with errors marked and the **Model avg** drawn as a dashed line, plus summary boxes:

| Box | What it tells you |
| --- | --- |
| **Last poll** | Duration of the latest poll and when it ran. |
| **Avg duration** | Average over the range, with the model average under it. |
| **Peak duration** | The slowest poll. |
| **Error rate** | Share of polls that failed, with the count, plus the number of partial polls when there are any. |
| **Avg queries** | SNMP queries per poll. |
| **Cycles** | Number of polls and the average interval between them. |

The table below lists every poll with **Start**, **Stop**, **SNMP Queries**, **Duration**,
**Model average** and **Errors**:

- **False** (green): the poll completed.
- **Partial** (amber): some SNMP requests in the poll timed out. Port alarms do not close or
  reopen on a partial poll; they wait for the next complete one.
- **True** (red): the poll failed.

Filter the **Errors** column by **Error**, **Partial** or **No error**. The range picker goes
back up to the last 30 days, and the download button exports every poll in the range as CSV.

**How to read it.** A device that is consistently several times slower than its model
average, or that has many partial polls, is slow to answer SNMP. That is a management-plane
problem: the device usually still forwards traffic, but its data in NetSense arrives late or
incomplete. OLTs with many ONUs are slower to poll by nature. Typical causes are a busy
device CPU, rate limits on SNMP or ARP on the device, or a congested path to the polling
agent. If one agent's devices all slow down together, see
[Running several polling agents](https://netsense-nms.com/docs/guides/polling-agents/).

## The Insights tab on OLTs

OLT pages have an **Insights** tab (it needs `onu:view`). Its first and only insight today is
**Flapping ONUs**: ONUs that keep changing state, which usually points at a fiber, connector
or splitter fault.

- Two counters: **Last 3 min** and **Last 24 hours**. Click one to list its ONUs below.
- An ONU counts as flapping from 5 cycles (the **Flapping count threshold** badge).
- The table shows **Cycles**, status, PON port, ONU index, **SN / MAC** and **Description**.
  Click the serial to open the ONU.

The two windows are counted differently. The 3-minute window uses the live flap counter,
where one down-and-up pair is a cycle; the 24-hour window counts stored down events. Compare
ONUs within one window, not across the two. Switch pages have no Insights tab.

For more on ONU states and down reasons, see [Monitoring ONUs](https://netsense-nms.com/docs/guides/monitoring-onus/).

## Server details

Servers report more about themselves than network devices. On a Linux server:

- **Device Information** on the Overview adds **OS**, **Architecture** and **Last Reboot**.
- The **CPU** tab lists each core by name with its **Utilization** and a 3-hour trend.
- The **Memory** tab lists physical, virtual and swap memory with usage, used and free.
- The **Storage** tab lists each disk or volume with **Usage**, **Used / Total** and **Free**.
- The **Disk I/O** tab lists each disk with **Reads** and **Writes** per second.

Tabs appear only when the server reports that data. Server alarm rules can use the same
readings, see [Creating alarm definitions](https://netsense-nms.com/docs/guides/alarm-definitions/).

Source: https://netsense-nms.com/docs/guides/device-health/index.mdx