title: "Ports, LAGs, sub-interfaces and custom speeds"
description: "Where NetSense lists ports and interfaces, how to read the port tables, how to set a custom speed, how LAGs and sub-interfaces are grouped, and what to check when a port shows no traffic or the wrong speed."
---

> Documentation Index
> Fetch the complete documentation index at: https://netsense-nms.com/docs/llms.txt
> Use this file to discover all available pages before exploring further.

# Ports, LAGs, sub-interfaces and custom speeds

Every port NetSense polls appears in three places: a fleet-wide list per device type, the
**Ports** tab of its device, and a detail page of its own. This guide explains what each
column means, how LAG members and sub-interfaces are grouped, and how to correct a speed
the device reports wrong.

## Where ports live

- **Fleet port lists.** Every device type in the sidebar has a **Ports** child:
  **OLTs → Ports**, **Switches → Ports**, **BNGs → Ports**, **Servers → Ports** and
  **Wireless → Ports**. Each lists the ports of every device of that type, sorted by
  utilization, highest first. The search box at the top has a field selector: pick what to
  search by (for example **Hostname**) before you type.
- **The device page.** Switches, BNGs, servers and wireless devices have a **Ports** tab.
  OLTs split it into **PON Ports** and **Uplink Ports**. Switches, BNGs and OLTs also have
  a **VLAN Interfaces** tab when the device reports VLAN interfaces, and a switch with
  coherent modules has a **Coherent Optics** tab.
- **The port detail page.** Click a port name in any list to open its own page. The page
  title says what kind of port it is: **PON Port**, **Ethernet Port** (an OLT uplink),
  **Switch Port**, **BNG Port**, **Server Port**, **Wireless Port**, **VLAN Interface** or
  **Coherent Module**. The breadcrumb at the top leads back to the device and the tab you
  came from.

Seeing ports needs the port permission of that device type, for example
`switch:port:view` or `olt:port:view`.

## Reading a port list

![The Switches Ports list sorted by utilization, with each port's status, switch, IP addresses, speed and type, Tx and Rx power, traffic in and out, bandwidth sparks, the Err./Disc. badges and utilization](https://netsense-nms.com/docs/_nimbus/md/3lthfd/ports-fleet-list.png)

| Column | What it shows |
| --- | --- |
| **Port** | Status dot, port name and description. A description you edited in NetSense is shown in blue. |
| **IP Addresses** | The addresses the device binds to the interface (see [IP addresses](#ip-addresses)). |
| **Speed** / **Type** | Interface speed (or your [custom speed](#custom-speed)) and the media type, such as copper or optical. |
| **Tx** / **Rx** | Optical transmit and receive power of the transceiver, in dBm. |
| **Temp.** | Transceiver temperature. |
| **Bandwidth IN / OUT** | Current traffic and a spark of the recent trend. |
| **Err.** / **Disc.** | One badge for errors and discards (below). |
| **Utilization (%)** | Current utilization against the port speed, with a spark. |
| **Last State Change** | When the port last went up or down. |

The **Err./Disc.** badge reads at a glance:

- a red **!** means errors, an amber **!** means discards, and a third color means both.
  Hover it to see the in and out rates per second.
- a green check means **No errors or discards**: every counter the port reports is zero.
- **-** means the port reports no error or discard counters at all.

**Filter by errors.** The **Err./Disc.** column header has a filter with **With errors**,
**Without errors**, **With discards** and **Without discards**. It applies to the whole list,
not only the page on screen. Errors and discards combine with AND, so **With errors** plus
**Without discards** finds ports that only have errors. Picking both the "with" and the
"without" option of the same kind cancels that kind out. The filter is on every fleet port
list.

**Sorting by a metric leaves out ports without a value.** Sort by Rx power and a copper
port, which has no Rx power, disappears from the list instead of sinking to the bottom. If a
port seems to be missing, clear the sort first.

**Choosing columns.** The sliders icon at the right end of the header row opens the column
list. **Select all** turns every column on, **Reset to default** goes back to the standard
set. Some columns show by default only on wider screens, so a laptop starts with fewer.
Your choice is remembered per table in your browser.

### On the device Ports tab

The device tab has the same information in more detail: **Errors**, **Discards** and
**Utilization** are split into IN and OUT, and the column list adds **Voltage** / **Bias**
for optical ports and **Unicast**, **Multicast** and **Broadcast** packet rates (all hidden
by default). On a switch, the toolbar filters by **Port Status**, **Trunk**, **Port Name**,
**Description** and **Utilization**.

Two more ways to look at the ports:

- **Expand a row** for that port's charts in place.
- **Chart view** (the chart icon next to the table icon, top right) draws one metric for
  every port of the device: bandwidth, utilization, errors, discards, Tx or Rx power,
  temperature, or a packet type. **Show disabled** adds administratively disabled ports.

## Custom speed

Some interfaces report the wrong speed or none at all: a LAG or bond that reports one
member's speed, a virtual interface that reports 0, a 10G port that carries a 2 Gbps
circuit. Utilization against the wrong speed is meaningless, so NetSense lets you set the
real one.

**To set it:** hover the speed in the **Speed** column, click the pencil (**Set custom
speed**), type the speed in **Mbps** as a whole number and confirm with the check button or
Enter. Clear the field (or enter 0) and confirm to go back to the reported speed. Press Esc
to cancel. The maximum is 10,000,000 Mbps.

You can do this on the device Ports tab, on the fleet port lists and on the **VLAN
Interfaces** tab of switches, BNGs and OLTs. It needs the port edit permission of that
device type: `switch:port:edit`, `bng:port:edit`, `olt:port:edit`, `server:port:edit` or
`wireless:port:edit`. VLAN interfaces on a switch use `switch:port:edit`.

A custom speed is shown in blue, and its tooltip gives the speed the device reports. From
then on NetSense uses it everywhere the speed matters:

- the speed shown for the port, VLAN or interface
- port utilization, and the total utilization of the device, so one device can mix custom
  and reported speeds
- utilization threshold alarms
- the utilization color of the link on [network maps](https://netsense-nms.com/docs/guides/network-maps/)

**When to use it:**

- **LAGs and bonds** whose reported speed is not the sum of their members, for example a
  MikroTik bond.
- **Sub-rate circuits**: a 10G port that carries a 2 Gbps transit contract, or a shaped
  customer port. Set the contracted rate and 80% utilization means 80% of what you pay for.
- **Interfaces that report no speed**, such as some VLAN interfaces and tunnels.

The custom speed belongs to that port. If a firmware or template change renames or
renumbers the port, set it again on the new one.

## LAGs and their members

On the **Ports** tab of a switch or BNG, LAG members are listed under their LAG
(Eth-Trunk, Port-channel, ae, bond), so the LAG and its links read as one group. The
**Trunk** filter shows one LAG with its members, or **No Trunk** for everything else.

The grouping is kept while you only filter by **Trunk**. As soon as you sort by a column or
add another filter, the table switches to a flat list.

The port detail page of a member shows the LAG it belongs to in its information panel.

## Sub-interfaces and VLAN interfaces

Routed traffic often lives on logical interfaces rather than on the physical port: dot1q
sub-interfaces (`GE0/0/1.100`, `Eth-Trunk5.4051`), Juniper units (`xe-0/0/1.0`,
`ae0.100`) and VLAN interfaces (`Vlanif22`). NetSense collects them with their status,
traffic and IP addresses on switches, routers and BNGs.

**Sub-interfaces are nested under their parent port** in the **Ports** tab, below the LAG
member they ride on if the parent is a LAG. Each shows its status, IP address and traffic.
They are **not counted** in the port totals or in the device traffic summary, so nothing is
counted twice, and they do not count as licensed nodes.

Today this nesting covers:

- **Juniper**: units on physical ports and on ae LAGs.
- **Huawei NetEngine routers**: dot1q sub-interfaces on physical ports and on Eth-Trunks.

On other vendors (for example Cisco and Nokia), sub-interfaces are not nested. Where the
device reports them as VLAN interfaces, they are listed in the **VLAN Interfaces** tab.
Nokia SR OS BNGs expose no per-VLAN interface objects; for their subscribers per VLAN see
[BNG subscriber sessions](https://netsense-nms.com/docs/guides/bng-subscriber-sessions/).

The **VLAN Interfaces** tab lists the L3 VLAN interfaces (`Vlanif`, `Vlan`, `VLAN2023`)
with their IP addresses, speed (which you can override), traffic and packet rates. On a BNG,
sub-interfaces are kept even when they carry no address of their own, so the interfaces that
terminate subscriber traffic are always listed.

**Alarms on sub-interfaces.** Port alarm rules can target sub-interfaces with the port type
**SubInterface**. It also works the other way round: a rule with `type == Ethernet` leaves
sub-interfaces out. See [Creating alarm definitions](https://netsense-nms.com/docs/guides/alarm-definitions/).

## IP addresses

The **IP Addresses** column is on the port lists and the device Ports tabs. Addresses are
collected on routed physical ports, bridge interfaces, LAGs, sub-interfaces and VLAN
interfaces, so an L3 switch or router shows what is really configured on each interface.
The BNG **Ports** tab and the **BNGs → Ports** list have the column too.

A port with no address shows nothing. That is normal for an L2 access or trunk port.

## MikroTik

MikroTik devices show every interface type, not only Ethernet, VLAN, bridge and bond:

- **PPP, VPN and wireless interfaces** with their status, traffic, packet counters, errors
  and IP addresses, so an outage on a tunnel that carries a whole segment is visible
- **EoIP tunnels**
- **Loopback** interfaces on RouterOS 7

On a MikroTik added as a BNG, dynamic subscriber sessions stay in the **Sessions** tab and
are not listed as ports.

Copper and optical ports are told apart reliably, including QSFP ports, SwOS devices and
ports you renamed, which used to show an unknown media type. The media type is what the
**Type** line under **Speed** shows, and it decides which ports get optical readings.

## Optics on ports

Ports with a transceiver show their optical readings:

- **Tx** and **Rx** power in dBm, and the module **Temp.** in the port lists
- **Voltage** and **Bias** current on switch and BNG optical ports (columns hidden by default)
- the module's own low and high thresholds for Tx and Rx power, where the module reports
  them

On a network map, the **Rx Power** and **Tx Power** toggles show the same readings at both
ends of a fiber link. Rx is colored against these thresholds, and a reading at or below
-40 dBm shows as "No light".

To read the optics from the device right now instead of waiting for the next poll, open the
port's actions menu (the three dots) and choose **Fetch Rx/Tx**. It is offered on OLT,
switch and BNG ports.

**Coherent Optics.** On switches with coherent modules (today the Edgecore 7716-24SC on
OcNOS), the **Coherent Optics** tab lists each module with **Laser Freq. (THz)**, **Rx
Power**, **Tx Power**, **Temp.**, **OSNR (dB)**, **Uncorrected FEC** and **Laser Age (%)**.
Each module has its own detail page, and the same readings are available in alarm rules.

## The port detail page

The page has a **Traffic** card with bandwidth, utilization, errors, discards and packet
rates, each drawn for several time ranges side by side (1 hour up to 180 days; you choose
which ranges are shown, and a normal-width window shows two at a time). Ports with a transceiver add a **Sensors** card with Tx power, Rx
power and temperature. Packet charts are not available for OLT PON and uplink ports. The
information panel on the right has the device, the port details (name, description, LAG,
speed, media type) and port statistics.

**Auto-refresh is off by default**, so a page left open does not keep loading data. Use the
refresh button to update now, or pick an interval from its menu: 1, 3, 5, 15 or 30 minutes.

From the actions menu you can also open **Live Traffic**, in place or in a new tab. How to
read and zoom the charts is covered in [Reading charts](https://netsense-nms.com/docs/guides/reading-charts/).

## Related

- **Alarm history of one port.** On the device's **Alarms** tab, filter by **Entity** and
  pick the port. With **Show history** on you get every down and up of that port over the
  date range, with the time each alarm opened and closed.
- **Interfaces port alarms skip.** On switches and BNGs some interfaces never raise port
  alarms, for example a port whose description contains `testing`. The list is in
  [Creating alarm definitions](https://netsense-nms.com/docs/guides/alarm-definitions/#match-conditions-vs-filter-conditions).
- **Which ports count as nodes.** LAGs, VLAN interfaces and sub-interfaces are not counted.
  See the [FAQ](https://netsense-nms.com/docs/reference/faq/#commercials).
- **Links and maps** are built on ports: see [Building network maps](https://netsense-nms.com/docs/guides/network-maps/).

## Troubleshooting

**A port or sub-interface shows zero traffic.**

- Check the port status first. A port on a device that is down shows its last known values.
- On Huawei NetEngine routers, a sub-interface reads 0 until traffic statistics are enabled
  on it on the router (`statistic enable` in the sub-interface view). The physical port
  counts normally.
- Some devices refresh their counters only every few minutes. Two polls with the same value
  are not a fault; look at a longer time range.
- If the port has traffic on the device and still reads 0 in NetSense after a few polls,
  contact Extreme Labs support with the device and port name.

**The speed or utilization is wrong.** The device reports the speed. If it reports one
member's speed on a LAG, 0 on a virtual interface, or the line rate of a sub-rate circuit,
set a [custom speed](#custom-speed). Utilization, alarms and map colors follow it on the next
poll.

**Sub-interfaces are missing.** Check which vendor the device is. Nesting in the **Ports**
tab covers Juniper and Huawei NetEngine; on other vendors look in the **VLAN Interfaces**
tab. If a Juniper or NetEngine device still lists none, make sure it is added with the
correct manufacturer and model (see [Adding devices](https://netsense-nms.com/docs/guides/adding-devices/)), then
contact Extreme Labs support. Supported models are listed in
[Supported vendors](https://netsense-nms.com/docs/reference/supported-vendors/).

**A port disappeared from the list.** Clear the sort: sorting by a metric hides ports that
have no value for it. Clear the **Err./Disc.** and status filters too.

Source: https://netsense-nms.com/docs/guides/ports-and-interfaces/index.mdx